A reset during an RTC read can leave the RTC holding SDA low. The next boot then hangs on the RTC probe, and pressing reset does not help because it does not reset the RTC.

This clocks SCL up to nine times before Wire.begin() so the RTC releases the bus. Tested on an M6 stuck this way: the debug log showed SDA=0 at boot, and the board now boots.

Thanks

A reset during an RTC read left SDA held low, and the RTC probe then
hung every boot. Up to nine clock pulses release the bus.